Indoor High Voltage Live Display Fault Indicator

Short Description:

Overview

A new type of detection equipment that monitors each circuit in real time, and can prompt or directly when the line fails.

Displaying faulty cables is of great significance for improving work efficiency and restoring power supply quickly.


Product Detail

Video

Product selection

Product Tags

The main function

1. Short-circuit current alarm: The short-circuit current sensor detects the running high-voltage cable online during operation,
When the line current reaches or exceeds the set value (which can be adjusted before leaving the factory according to user needs), short-circuit
The sensor sends an alarm signal and transmits it to the host through the optical fiber. After the host receives the signal, it will be displayed on the panel
The corresponding alarm indication signal is issued, and some models can also send the signal directly to the main control system.
2. Ground current alarm: The ground current sensor detects the ground current of the user cable.
When the current reaches or exceeds the set value (it can be adjusted before leaving the factory according to user requirements), the ground current
The sensor sends out an alarm signal and transmits it to the host through the optical fiber. After the host receives the signal, it sends out an alarm on the panel.
Corresponding alarm indication signal, some models can also send the signal directly to the main control system.
3. Automatic reset: When the host sends an alarm signal, no one will be in 12 hours (or other customized time)
Work reset, the indicator will reset automatically.
4. Manual reset: When the indicator is in the alarm state, by pressing the reset button on the host, the alarm can be released.
Manual reset to alarm state.
5. Test: The host can perform self-test through the reset/test button on the panel, press the panel continuously
After pressing the reset/test button for about 2s, the host enters the self-built state, the indicator light on the panel lights up, and the output continues.
The electrical appliance is closed for a period of time to check that the working state is normal.
6. Temperature test and alarm (temperature measurement type): The temperature measurement type short-circuit sensor is in the working state to the high voltage cable.
The temperature is detected online and transmitted to the host LCD screen in real time when the temperature changes greatly. When the temperature exceeds
When over 60°, the host screen will flash alarm. When the master control system sends a transmission signal request, the master will
Fault and temperature signals are sent to the main control system.

Diagram

Product name

Product model

Basic function

Remarks

Fault indicator

EKL2

 product-description1

EKL panel fault indicator is a real-
time monitoring device installed
on the central network switch
cabinet,cable branch box and
box transformer,which is used
to indicate the short circuit of
the corresponding cable section
and single-phase ground failure

Open hole is
92mm * 45mm

EKL4

EKL5

Wireless temperature measurement

Wiring diagram

product-description2

Hole size(panel):
92.5mm ±0.3mm ×43.5mm±0.3mm
· Complete product composition:
· Main machine *1 short circuit sensor*3
· Grthing sensor*1 Four optical fibers*1

Terminal diagram

product-description3

Technical parameter

Applicable voltage level: 6-35KV
Applicable load: 0-600A
Applicable wire current: I≤1000A
Applicable wire diameter: 25mm²≤d≤400mm²
Action response time: 0.06S≤T≤3S
Static power consumption: ≤10μW
Action reset time: 6, 12, 24, 36 hours optional
Ambient temperature: -40℃≤T≤+75℃
Action times: >4000 times
Ground fault pickup value: Factory default 20A, 20ms
(5-50A can be customized with an accuracy of ±10%)
Short-circuit fault start value: factory default 800A, 20ms
(300-1500A can be customized, accuracy ±10%)

Installation method and installation diagram

1. The main unit of the indicator is installed on the front panel of the power distribution cabinet

product-description4

2. Install the three short-circuit current sensors on the A, B, and C phases of the cable respectively, and they must be tightly sleeved on the line to be detected.

product-description5

3. Install the ground current sensor at the lower end of the three-phase cable, and its magnetic yoke should surround the three phases.
4. Structure diagram after installation:

product-description6

Applications

product-description7


  • Previous:
  • Next:

  • product name

    product model

    basic function

    remarks

    fault indicator

    EKL2

    图片1

    EKL panel fault indicator is a real-time monitoring device installed on the central network switch cabinet, cable branch box and box transformer, which is used to indicate the short circuit of the corresponding cable section and single-phase ground failure

    Open hole is 92mm * 45mm

    EKL4

    EKL5

    Wireless temperature measurement

    Write your message here and send it to us

    Related products

    • Microcomputer Harmonic Elimination Device

      Microcomputer Harmonic Elimination Device

      Functions and Features ●Modular design, compact structure, advanced technology, high-speed 32-bit ARM core processor ensures real-time operation and action accuracy. ●Real-time monitoring of system status, real-time calculation, accurate judgment of low-frequency, fundamental frequency, high-frequency resonance faults in the system, and timely action. ●Real-time display of three-phase voltage, opening voltage, can accurately determine grounding, overvoltage and under...

    • Indoor High Voltage Live Display

      Indoor High Voltage Live Display

      Product Details Overview This product is a HX2 phase comparator (PC) designed and produced by our company according to the requirements of users, which is used in conjunction with the DXN80 series of indoor high-voltage live display devices (the indicator panel sets the phase test end). It is suitable for substations and power distribution stations (especially when cables enter the line) that are equipped with dual power supplies and multiple power supplies for in...

    • Current Transformer Secondary Overvoltage Protector

      Current Transformer Secondary Overvoltage Prote...

      scope of application Current transformer secondary overvoltage protector is mainly suitable for differential winding, overcurrent winding, measurement winding, bus protection winding and backup winding of CT secondary side. It is used to inhibit transient overvoltage below impact overvoltage of the equipment and discharge surge energy, so as to protect the system circuit and equipment. Normal service conditions and installation conditions 1. Normal service conditions...

    • Intelligent Dehumidification Device Intelligent Oil Pumping Device Mini

      Intelligent Dehumidification Device Intelligent...

      Overview Intelligent dehumidification device is the use of semiconductor refrigeration dehumidification mode, the humid air in the closed space under the action of the fan inhalation dehumidification air duct, the water vapor in the air through the semiconductor refrigeration mechanism condensed into water, and then through the guide pipe through the cabinet, can achieve a good dehumidification effect. When there is no manual open dehumidification function: when the ...

    • Small Current Grounding Line Selection Device

      Small Current Grounding Line Selection Device

      Model and parameters and service environment Table 1 of Technical Parameters of Small Current Line Selection Device Technology, technique, reference, and mark Technology, technique, reference, and number Prepare, note working voltage AC/DC:85V~265V Input the opening zero-order voltage, U0x 0~150V The measurement accuracy is 1% Enter zero-order current 20mA~3A The measurement accuracy was 0.5% Select line range There are 54 bus rou...

    • Intelligent Dehumidification Deviceintelligent Oil Pumping Deviceconventional

      Intelligent Dehumidification Deviceintelligent ...

      Summary Intelligent dehumidification device is the use of semiconductor refrigeration dehumidification mode, the closed space of the wet air in the fan under the action of the fan, the air water vapor through the semiconductor refrigeration mechanism after condensing into water, and then eliminate the cabinet through the guide pipe, can achieve a good dehumidification effect. Cooling type: F01 is set at 0. Meanwhile, the dehumidification device is automatically start...