We normally follow the basic principle Quality Initial, Prestige Supreme. We've been fully committed to offering our consumers with competitively priced good quality merchandise, prompt delivery and professional support for Single Phase Motor Protection, Amp Meter 12v, Dual Power Meter, Adhering to the business principle of mutual benefits, we have won good reputation among our customers because of our perfect services, quality products and competitive prices. We warmly welcome customers from home and abroad to cooperate with us for common success.
ODM Digital Volt And Amp Meter Factory - LED Digital Display Meter – Newlink Detail:

ltem/Model (Emerald Backlight) (white backight optional negative display white characters)
Shape  1  2
Working power DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
Dimensions (WwH’Dmm) 79×42.5×25.5 79×42.5×25.5
Mounting hole(mm) 75×39.5 75×39.5
Measurement accuracy ±0.2% of full scale value ±2 words(DC)
+0.5% full scale value ±5 words (AC)
±0.2% of full scale value +2 words(DC)
±0.5% full scale value 15 words(AC)
Basic rangeo DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/300V 200mV/2V/20V/200V/300V
DC current (dired input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
AC current (direct input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
Extended range (external input) AC transfomer. DC shunt Voltage drop module AC transfomer. DC shunt Voltage drop module
Display character height 20×10mm LCD show 20× 10mm LCD show
Features Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
Other +/-polarity automatic switching, optional reading lock function +/-polarity automatic switching, optional reading lock function
ltem/Model (negative emerald green characters) (Negatve white characters can be selected with white backlight)
Shape  1  2
Working power DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
Dimensions (WwH’Dmm) 79×42.5×25.5 79×42.5×25.5
Mounting hole(mm) 75×39.5 75×39.5
Measurement accuracy ±0.2% of full scale value ±2 words(DC)
+0.5% full scale value ±5 words (AC)
±0.2% of full scale value +2 words(DC)
±0.5% full scale value 15 words(AC)
Basic rangeo DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/300V 200mV/2V/20V/200V/300V
DC current (dired input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
AC current (direct input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
Extended range (external input) AC transfomer. DC shunt Voltage drop module AC transfomer. DC shunt Voltage drop module
Display character height 20×10mm LCD show 20× 10mm LCD show
Features Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
Other +/-polarity automatic switching, optional reading lock function +/-polarity automatic switching, optional reading lock function

If the power supply DC5V is used to measure AC300V or AC500V, it is recommended to use the power supply AC9V to measure AC300V or AC500V, which saves 30%-50% of production costs.

(Blue backlight optional negative blue words) (Orange backlight optional negative orange word) (Red backlight optional negative red words) (negative green words)
 1  2  3  4
DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V
79×42.5×25.5 79×42.5×25.5 79×42.5×25.5 79×42.5×25.5
75×39.5 75×39.5 75×39.5 75×39.5
±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC)
±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC)
200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V
200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
20×10mm LCD display 20×10mm LCD display 20×10mm LCD display 20×10mm LCD display
Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
(negative blue characters, optional blue backlight) (Negative orange characters, optional orange backlight) (negative red words, backlight optional red) (green backlight word)
 5  6  7  8
DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V
79×42.5×58 79×42.5×58 79×42.5×58 79×42.5×58
75×39.5 75×39.5 75×39.5 75×39.5
±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC)
±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC)
200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V
200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
20×10mm LCD display 20×10mm LCD display 20×10mm LCD display 20×10mm LCD display
Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

3 and a half LED digital display meter product selection

The main technical parameters

Shape  1  2
Working power DC5V±5%≤ 100mA AC/DC9V-12V AC/DC24V-48V DC5V±5%≤ 100mA AC/DC9V-220V AC110-220V
Dimensions (W’H’Dmm) 79×42.5×25.5 79×42.5×58
Mounting hole(mm) 76×39.5 76×39.5
Measurement accuracy ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
Basic range DC voltage (direct input) 200mv / 2V / 20V / 200V / 500V 200mv / 2V / 20V / 200V / 500V
AC voltage(direct input) 200mv / 2V / 20V / 200V / 300V 200mv / 2V / 20V / 200V / 500V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 10A
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 10A
Extended range (external input) AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
Display character height 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Features Fully enclosed gray shell, curved design, embedded installation Fully enclosed gray shell, curved design, embedded installation
Other +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
Shape  1  2
Working power DC5V±5%AC/DC9V-12V AC/DC24V DC5V±5%≤ 100mA
Dimensions (W’H’Dmm) 48×26×35 48×26×23
Mounting hole(mm) 47×23 47×23
Measurement accuracy ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 digits (DC)
Basic range DC voltage (direct input) 200mv / 2V / 20V / 200V / 500V 200mv / 2V / 20V / 200V
AC voltage(direct input) 200mv / 2V / 20V / 200V / 300V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A
Extended range (external input) AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
Display character height 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Features Delicate appearance, small and exquisite, embedded design Delicate appearance, small and exquisite, embedded design
Other +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

If the power supply DC5V is used to measure AC300V or AC500V, it is recommended to use the power supply AC9V to measure AC300V or AC500V, which saves 30%-50% of production costs.

 1  2  3  4
DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%AC/DC9V-12V AC/DC24V DC5V±5%≤100mA
71×40×28 71×40×58 46×26×20 48×29×30
68×38 68×38 42×23 46×265
±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V
200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/10A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/10A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Fully enclosed gray shell, curved design, embedded installation The shell size is the same as that of the 85L/85C series pointer head, which can be directly interchanged Exquisite shape, small and exquisite, embedded design Exquisite shape, small and exquisite, embedded design
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
 1  2  3
DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-220V AC110-220V
72×36×20 79×42.5×20 74×32×69
69×34 76×39.5 70×28
±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V
200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Plug-in self-locking device, easy to install Black shell, embedded installation, elegant appearance Fully enclosed gray housing, flat design, ejector clamp installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

4 and a half LED digital display meter product selection

The main technical parameters

Shape  product description1  product description2
Working power DC5V±5%≤150mA DC5V土5% S 150mA AC/DC9V-12V AC/DC24V-48V
Dimensions (W’H'Dmm) 79×42.5×25.5 79×42.5×58
Mounting hole(mm) 76×39.5 76×39.5
Measurement accuracy ±0.03% full scale value ±2 words(DC) ±0.03% full scale value ±2 words(DC) ±0.5% full scale value ±35 words(AC)
Basic range DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/500V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A
Extended range (external input) DC shunt, voltage drop module AC Transformer, DC Shunt,Voltage Drop Modu
Display character height 0.56LED red(optional green,yellow or blue)
Features Totally enclosed gray shell, curved design, embedded installation
Other +/-polarity automatic switching, optional reading lock function
Shape

product description3

product description4

Working power DC5V±5%≤150mA AC/DC9V-220V AC110-220V DC5V±5%≤150mA AC/DC9V-220V AC110-220V
Dimensions (width x height x depth mm) 96×48×86 96×48×117
Mounting Hole(mm) 90×45 91×44
Measurement precision ±0.5% full scale value ±35 words (AC) ±0.5% full scale value ±35 words (AC)
Basic range (direct input) AC200mV-500V AC200μA-5A AC200mV-500V AC200μA-5A
Extended range (external input) AC transformer AC transformer
Frequency Range 45-400Hz AC 45-400Hz AC
Display method 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue)
Product Features Fully enclosed gray shell, flat design, screw-tight installation Fully enclosed gray shell, flat design, screw-tight installation
Others +/- polarity automatic conversion, optional reading lock function. Optional with RS-485 interface, upper limit, lower limit setting, with transmitter output function. +/- polarity automatic conversion, optional reading lock function. Optional with RS-485 interface, upper limit, lower limit setting, with transmitter output function.
 product description5

 product description6

 product description7

 product description8

DC5V±5%≤100mA AC/DC9V-12V AC/DC24V-48V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%≤100mA AC/DC9V-220V AC110-220V
74×32×69 9×48×77 96×48×86 95×.48×117
70×28 9×45 90×45 91×44
±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC)
200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/750V
200mV/2V/20V /200V/300V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/750V
200μA/ 2mA/ 20mA/ 200mA/2A/ 5A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 15A
200μA/ 2mA/ 20mA/ 200mA/2A/ 5A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 15A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue)
Fully enclosed idle ash shell, flat design, ejector clamp installation Fully enclosed gray shell, flat design, embedded installation Fully enclosed gray housing, flat design, screw-fastened installation Fully enclosed gray housing, flat design, screw-fastened installation
+/- polarity automatic switching. Optional reading locking function +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function. +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function. +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function.

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

3 and a half LED digital display meter

The main technical parameters

shape

 product description1

 product description2
working power supply

AC/DC9V-12V AC/DC24V AC-220V
(Two-wire direct measurement. No working voltage required)

AC/DC9V-12V AC/DC24V AC-220V
(Two-wire direct measurement. No working voltage required)

Dimensions (width x height x depth mm)

70×40×25

70×40×25
Mounting Hole(mm)

68×38

68×38

product description3

Suggestion: The digital AC ammeter is in the measurement range of 10A-300A. It is recommended to use a precision current transformer (see pages 49-51 for technical specifications), which saves 30%-50% in production costs.

Shape

 product description4

Working power AC220v
Dimensions (width x height x depth mm) 96×48×117
Mounting Hole(mm) 90×43
Measurement precision Main 0.2% full scale value ±2 words (DC). ±0.5% full scale value ±5 words (AC)

product description5


Product detail pictures:

ODM Digital Volt And Amp Meter Factory - LED Digital Display Meter – Newlink detail pictures


Related Product Guide:

We have a highly efficient team to deal with inquiries from customers. Our goal is 100% customer satisfaction by our product quality, price & our team service and enjoy a good reputation among clients. With many factories, we can provide a wide range of ODM Digital Volt And Amp Meter Factory - LED Digital Display Meter – Newlink , The product will supply to all over the world, such as: Munich, Hongkong, Hongkong, It is our customers' satisfaction over our products and services that always inspires us to do better in this business. We build mutually beneficial relationship with our clients by giving them large selection of premium car parts at marked down prices. We offer wholesale prices on all our quality parts so you are guaranteed greater savings.
  • The factory can meet continuously developing economic and market needs, so that their products are widely recognized and trusted, and that's why we chose this company.
    5 Stars By May from Ghana - 2018.09.12 17:18
    We are a small company that has just started, but we get the company leader's attention and gave us a lot of help. Hope we can make progress together!
    5 Stars By Bess from South Africa - 2017.03.28 16:34
    Write your message here and send it to us

    Related products

    • OEM High Quality Small Dc Voltmeter Manufacturers - Active and Reactive Frequency Table (Regular) – Newlink

      OEM High Quality Small Dc Voltmeter Manufacture...

      Smart Frequency Meter Instruction Manual Product Features 1. The whole four-digit display 2. Optional with communication function, communication address, baud rate 3. Software adjustment, no internal potentiometer, high precision 4. Software adjustment, no internal potentiometer, high precision Matters needing attention 1. Before use, the meter needs to be powered on for 15 minutes. 2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmf...

    • ODM Intelligent Control Device Voltmeter Manufacturer - Single-Phase Multi-Function Power Meter (Design Version) – Newlink

      ODM Intelligent Control Device Voltmeter Manufa...

      Overview The single-phase multi-function meter can measure all the commonly used power parameters in the power grid system with high precision: single-phase voltage, single-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with communication Interface and energy pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of conv...

    • ODM Home Electric Meter Supplier - Three-Phase Voltmeter (Conventional) – Newlink

      ODM Home Electric Meter Supplier - Three-Phase...

      Overview Using AC voltage technology, it is possible to measure the three voltage phases in the power grid, and simply compare them through the panel setting rate. Features, and can complete the network communication with similar PLC and industrial computer. Features Measurement: Three-phase voltage Display: Three rows of LED digital / LCD liquid crystal display A, B, C three-phase voltage Uses: suitable for power grid, automatic control system. Low-voltage three-phase current measurement cir...

    • OEM High Quality Digital Cluster Display Manufacturer - Intelligent Temperature And Humidity Controller – Newlink

      OEM High Quality Digital Cluster Display Manufa...

      Application

    • OEM High Quality Wall Wattage Meter Suppliers - Single-phase Voltmeter (Design Version) – Newlink

      OEM High Quality Wall Wattage Meter Suppliers -...

      Overview The smart voltmeter adopts AC sampling technology, can measure the voltage in the power grid, and can set the magnification through the panel buttons, which is very cost-effective. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phas...

    • OEM High Quality Prepaid Power Meter Factories - Multifunctional Power Meter (Design version) – Newlink

      OEM High Quality Prepaid Power Meter Factories ...

      Overview The multi-function power meter can measure all the commonly used power parameters in the three-phase power grid system with high precision: three-phase voltage, three-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with Communication interface and power pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of co...