    Electronic Hygrothermostat ETF012

    ●Temperature and humidity adjustable ●Optical operating display(LED) ●HIgh switching capacity ●Clip fixing The electronic hygrotherm senses the ambient temperature and relative humidity in anenclosure with electric/electronic component,and turns on a heater(or alternatively,a fan)ateither set point.helping prevent the formation of condensation in the enclosure. The LEDintegrated in the adiustment knob on the active controller is lit when the connected devicelS in operation. Technical...
  • Mechanical Thermostat FZK 011

    Mechanical Thermostat FZK 011

    ●Adjustable temperature ●High switching capacity ●Small hysteresis ●Terminals easily accessible ●Clip fixing ●Change-over contact The mechanical thermostat is used for controlling heating and cooling equipment,filter fans or signal devices.The thermostat registers the surrounding ai r and can switch both inductive and resistive loads via snap-action contact. Technical Data Switch temperature difference 4K(±1.5K tolerance) Sensor element Thermostatic bimetal Contact type snap-action ...
  • Tamperproof  Thermostats(pre-set)FTO 011/FTS 011

    Tamperproof Thermostats(pre-set)FTO 011/FTS 011

    ●Small size ●Default temperature settings ●Easy to install ●High switching tolerance Tamperproof(Pre-set)Thermostat FTO 011 Contact breaker/NC(red casing)for regulating heaters or for switching signal devices when temperature has fallen below the minimum value.The contact opens Wnen temperatu re is rlslna. Tamperproof(Pre-set)Thermostat FTS 011 Conact maker/NO(blue casing)for regulating filter fans,heat exchange rs,cooling devices or for switching signal devices when temperatu re li...
  • Mechanical Hygrostat MFR 012

    Mechanical Hygrostat MFR 012

    ●Adjustable relative humidity ●Change-ove r Contact ●High switching capacity ●Easily accessible te rminals ●Clip fixinq The electromechanical hygrostat MRF 012 is designed to control enclosure heaters sothat the dew point is raised when a critical relative humidity of 65%is exceeded. In thisway condensation and corrosion is effectively prevented. Technical Data Switch difference 4% relative humidity (±3% tolerance) Permissible air velocity 15m/sec Contact type change-over contact C...
  • Dual Thermostat ZR 011

    Dual Thermostat ZR 011

    ●NO and NC in one casing ● Separate adjustable tempe ratures ●High switching capacity ●Terminals easily accessible ●Clip fixing Two thermostats in one casing: Thermostat(contact breaker,normally closed)for regulating heaters. Thermostat(contact maker,normally open)for regulating filter fans and heat exchangers or switching signal devices when temperature limit has been exceeded. Heaters and cooling equipment can be switched independently from each orther with atemperature offset as opp...
  • Small,Compact Thermostat FKO 011/FKS 011

    Small,Compact Thermostat FKO 011/FKS 011

    ●Large setting range ●Small size ●Simple to mount ●High switching performance FKO 011:The rmostat(normally closed),contact breaker for regulating heaters. FKS 011:Thermostat(normally open),contact maker for regulating of filter fans and heat exchangers or for switching signal devised when temperature limit has been exceeded. Technical Data Switch temperature difference 7K(±4K tolerance) Sensor element thermostatic bimetal Contact type snap- action contact Contact resistance...
  • Small,Compact Thermostat KTO 011/KTS 011

    Small,Compact Thermostat KTO 011/KTS 011

    ●Large setting range ●Small size ●Simple to mount ●High switching performance KTO 011:The rmostat(normally closed),contact breaker for regulating heaters. KTS 011:Thermostat(normally open),contact maker for regulating of filter fans and heat exchangers or for switching signal devised when temperature limit has been exceeded. Technical Data Switch temperature difference 7K(±4K tolerance) Sensor element thermostatic bimetal Contact type snap- action contact Contact resistance...
  • Pressure Compensation Device DA 084

    Pressure Compensation Device DA 084

    ●High degree of protection ●Easy to insta ①It has become more and more important to provide a protected enclosure environment for valuable and crucial electrical and electronic components. ②In a tightly closed enclosure.pressure differentials can occur during extreme temperatu re variations.such as day/night operation. ③hen this occurs,the risk of dust and humidity being absorbed into the control panel increases dramatically. ④The specially designed pressure compensation plug DA 084 permits ...
  • SK3110.000 Series of Electronic Thermostat

    SK3110.000 Series of Electronic Thermostat

    Inner temperature controller for switchgear cabinet Especially used for controlling fan filter,heater and exchanger.also could be monitoring the electric cabinetinner temperature when working as signal arcuser. Technical Data Make bimetal sensor as heat sensitivity set to feedback of heat. Contact point scheme:single switch over contact point as instant switch component allowed load of contact point KL5-3  ACI0(4)A DC=30WKL5-4(Cooling) AC5(4)DA  DC=30W (D)=sensitivity load at COS∅ =0...
  • SG-7000 Series of Mechanical Thermostat

    SG-7000 Series of Mechanical Thermostat

    Use instructions Room thermostat Bimtallic room thermostat for heating and air-conditioning installations Thermal, electrical and mechanical features Breaking capacity on opening contact,10A-250V A.C.(ohmic load) Differential:0.5K Temperature’s scale adjustment After almost two days from the installation, to obtain a precise scale adjustment, measu re the room tempe rature with a reference thermomete r, placed aside the thermostat, holding the shagreened part of the knob, turn the index...
  • SG-2000 Series of  Mechanical Thermostat

    SG-2000 Series of Mechanical Thermostat

    Technical Data Appication:control of central air conditioner or heating Temperature control range:10℃~30℃ Work voltage:220V~/50HZ Max load:10A Technical Drawing
  • SG-6000 Series of  Mechanical Thermostat

    SG-6000 Series of Mechanical Thermostat

    Introduction The RTC70.xx iS used for 2-position contr01 with on/off output for the control the temperature by means of an NTC sensor placed externally or internally in the thermostat.the thermostat acquires the room temperatu re with its built-in sensor or floor sensor.and the heating contact will close when the room temperatu re falls below the selected setpoint. Application For the control of warm-water(floor)heating systems and direct electric heating systems used in Commercial building...