• facebook
  • linkedin
  • Instagram
  • youtube
  • WhatsApp
  • nybjtp

Tamperproof Thermostats(pre-set)FTO 011/FTS 011

Short Description:


Product Detail

Video

Product selection

Product Tags

●Small size

●Default temperature settings

●Easy to install

●High switching tolerance

Tamperproof(Pre-set)Thermostat FTO 011 Contact breaker/NC(red casing)for regulating heaters or for switching signal devices when temperature has fallen below the minimum value.The contact opens Wnen temperatu re is rlslna.

Tamperproof(Pre-set)Thermostat FTS 011

Conact maker/NO(blue casing)for regulating filter fans,heat exchange rs,cooling devices or for switching signal devices when temperatu re limit has been exceeded.

The contact closes when temperau re is rising.

Technical Data
Sensor element Thermostatic bimetal
Contact type Snap-action contact
Contact resistance <20mΩ
Service life >100,000 cycles
Max Switching capacity 250V AC,5(1.6)A
120V AC,10(2)A
DC 30W
Max inrush current AC 10A
EMC acc to EN55014-1-2.EN 61000-3-2.EN 61000-3-3
Connection 2-pole terminal for 2.5mm2,torque O.8Nm max
Mounting clip for 35mm DIN rail.EN60715 or for exit filter EF118 Series
Casing Plastic UL94 standard V-0 fire rating
Dimensions 47×33 x 33mm
Weight Approx.23g
Fitting position Variable
Operating Strage temperature -20 to+80℃(-4 to+176°F)/-45 to+80℃(-49 to+176°F)
Protection type IP20
wps_doc_15
wps_doc_16
wps_doc_17

  • Previous:
  • Next:

  • product name

    product model

    basic function

    remarks

    Temperature-fixed thermostat controller

    FTO 011

    图片7

    Plus can start when the temperature drops to a fixed value

    Heat device or switch signal device

    Hole dimensions 47 * 33 * 33

    Temperature-fixed thermostat controller

    FTS 011

    图片8

    When the temperature drops to a fixed value, the fan cooling device can be activated

    Hole dimensions 47 * 33 * 33

    Write your message here and send it to us

    Related products

    • Molded case circuit breaker

      Molded case circuit breaker

      Technical Parameters Product Name Specifications Rated current MCCB M1-63L/3300 10、16、20、25 、32、40、50、 63 MCCB M1-63M/3300 MCCB M1-63M/4300A MCCB M1-63M/4300B MCCB M1-125L/3300 16A 20A 25A 32A 40A 50A 63A 80A 100A 125A MCCB M1-125L/4300A MCCB M1-125L/4300B MCCB M1-125M/3300 MCCB M1-125M/4300A MCCB M1-125M/4300B ...

    • Single-channel electrical fire monitor

      Single-channel electrical fire monitor

      Basic functions The type electrical fire monitoring detector can realize real-time monitoring and collection of the residual current and temperature value of the controlled circuit, and will send out an audible and visual fault alarm signal when the fault alarm data of the detection circuit is collected; it can also be networked with the electrical fire monitoring host, and the monitoring host can Judging the state of the on-site detectors, the host computer analyzes and processes to indicate...

    • Three-Phase Guide Rail Multifunctional Meter

      Three-Phase Guide Rail Multifunctional Meter

      Safety Guidance Information about your personal safety Due to different conditions or requirements, this manual cannot cover all the safety matters related to the operation of this instrument, but it is very important to understand the following items to ensure your personal safety and prevent damage to the instrument. These items are highlighted with a triangular safety symbol, depending on the degree of potential hazard indicated. ...

    • Filter Fan FK 6626

      Filter Fan FK 6626

      Technical Data Model FK6626.230 FK6626.115 Standard fan F2E-260B-230 F2E-260B-115 Rated working voltage(V) 230/50/60 115/50/60 Air flow 190/220m³/h Air flow distribution export filters 1xFK6626.230:360/390m³/h 2xFK6626.230:440/495m³/h Axial flow fan capacitance electric Rated current (A) 0.29/0.33 0.62/0.65 Power 13/15 61/71 The noise level (db) 59/61 Working temperature range -10℃ to +55°℃ Export filter model ...

    • Current Transformer Secondary Overvoltage Protector

      Current Transformer Secondary Overvoltage Prote...

      scope of application Current transformer secondary overvoltage protector is mainly suitable for differential winding, overcurrent winding, measurement winding, bus protection winding and backup winding of CT secondary side. It is used to inhibit transient overvoltage below impact overvoltage of the equipment and discharge surge energy, so as to protect the system circuit and equipment. Normal service conditions and installation conditions 1. Normal service conditions...

    • Combined Electrical Fire Monitor

      Combined Electrical Fire Monitor

      Shape and installation dimensions   Product information Product model: NLK888DDS Rated operating current IN (A): 16A~1600A Rated working voltage UE (V): AC220V Residual current warning and alarm value: 20mA~1000mA can be set arbitrarily Three-phase current warning and alarm value: no Temperature warning and alarm value: 20°C~150°C can be set arbitrarily Number of leakage circuits: 1~16 circuits Number of temperature loops: 1~8 loops Alarm protection: protection or no protection can be set Pro...