Molded case circuit breaker
Technical Parameters
Product Name |
Specifications |
Rated current |
MCCB |
M1-63L/3300 |
10、16、20、25 |
MCCB |
M1-63M/3300 |
|
MCCB |
M1-63M/4300A |
|
MCCB |
M1-63M/4300B |
|
MCCB |
M1-125L/3300 |
16A 20A 25A 32A |
MCCB |
M1-125L/4300A |
|
MCCB |
M1-125L/4300B |
|
MCCB |
M1-125M/3300 |
|
MCCB |
M1-125M/4300A |
|
MCCB |
M1-125M/4300B |
|
MCCB |
M1-250L/3300 |
125A 140A 160A |
MCCB |
M1-250L/ 4300A |
|
MCCB |
M1-250L/ 430OB |
|
MCCB |
M1-250M/3300 |
|
MCCB |
M1-250M/4300A |
|
MCCB |
M1-250M/4300B |
|
MCCB |
M1-400/3300 |
225A 250A 315A |
MCCB |
M1-400/4300A |
|
MCCB |
M1-400/4300B |
|
MCCB |
M1-630/3300 |
400A 500A 630A |
MCCB |
M1-630/4300A |
|
MCCB |
M1-630/4300B |
|
MCCB |
M1-800/3300 |
630A 700A 800A |
MCCB |
M1-800/4300A |
|
MCCB |
M1-800/4300B |
|
MCCB |
1-1250/3300 |
1000A 1250A |
MCCB |
M1-1250/4300 |
|
MCCB |
M1-1600/3300 |
1600A |
MCCB |
M1-1600/4300 |
Product Name |
Specifications |
Rated current |
LMCCB |
M1LE-125/3300 |
16-125A |
LMCCB |
M1LE-125/4300A |
|
LMCCB |
M1LE-125/4300B |
|
LMCCB |
M1LE-250/3300 |
|
LMCCB |
M1LE-250/4300A |
100-250A |
LMCCB |
M1LE-250/4300B |
|
LMCCB |
M1LE-400/3300 |
225-400A |
LMCCB |
M1LE-400/4300A |
|
LMCCB |
M1LE-400/4300B |
|
LMCCB |
M1LE-630/3300 |
400-630A |
LMCCB |
M1LE-630/4300A |
|
LMCCB |
M1LE-630/4300B |
|
LMCCB |
M1LE-800/3300 |
630-800A |
LMCCB |
M1LE-800/4300A |
|
LMCCB |
M1LE-800/4300B |
|
LMCCB |
NM1L-1250/4300 |
|
LMCCB |
NM1L-1600/4300 |
Product Name |
Specifications |
Rated current |
EMCCB |
M1E-125M/3300 |
16-125A |
EMCCB |
M1E-125M/4300A |
|
EMCCB |
M1E-125M/4300B |
|
EMCCB |
M1E-250M/3300 |
100-250A |
EMCCB |
M1E-250M/4300A |
|
EMCCB |
M1E-250M/4300B |
|
EMCCB |
M1E-400M/3300 |
200-400A |
EMCCB |
M1E-400M/4300A |
|
EMCCB |
M1E-400M/4300B |
|
EMCCB |
M1E-630M/3300 |
400A-630A |
EMCCB |
M1E-630M/4300A |
|
EMCCB |
M1E-630M/4300B |
|
EMCCB |
M1E-800M/3300 |
630-800A |
EMCCB |
M1E-800M/4300A |
|
EMCCB |
M1E-800M/4300B |
APPLICATION
M1series of moulded case circuit breaker is one of our new type products developed and manufactured by adopting international advanced technology. It is supplied with rated insulating voltage 800V and used for circuit ofA.C.50/60Hz, rated operating voltage AC 400V.(or below), rated operating current up to 1600A for infrequent changing over and starting of the motors.
Equiped with the protection devices for over-current, short circuit and undervoltage, the products are capable of preventing damage of circuits and supply units.
The products conforms to GB14048.2, IEC60947-2 stardands.
TYPES AND MEANINGS
Note:*No code for distribution breakers;"2"represents motor protection circuit breakers.
*No code for direct handle operation;"P"represents electrical operation,and"Z"represents rotary-operated- handles.
*Rated breaking capacity grade of MCCB,C-Economical type L-Stardand type M-Middle high breaking capacity type,H-High breaking capacity type.
CLASSIFICATION OF MCCB
According to product poles, two kinds of three-pole and four-pole are provided, The neutral pole (N pole) of four pole has four types:
Type A: No current trip-release on N pole which making all the time; not closing and opening with the other three poles.
Type B: No current trip-release on N pole which closing and opening with the other three poles.
Type C: With current trip-release on N pole which closing and opening with the other three poles.
Type D: With current trip-release on N pole which making all the time; not closing and opening with the other three poles.
MAIN TECHNICAL SPECIFICATIONS
Type |
Rated |
Pole |
Rated |
Rated |
Arcing-Over |
Ultimate short |
Service Short |
Operation |
|
ON |
OFF | ||||||||
M1-63S |
6,10,16,20,25 |
Three |
500V |
400V |
0 |
25 |
18 |
1500 |
8500 |
M1-63H |
0 |
50 |
35 |
||||||
M1-100L |
10,16,20 |
800V |
0 |
25 |
18 |
||||
M1-100S |
0(≤50) |
35 |
22 |
||||||
M1-100H |
0(≤50) |
50 |
35 |
||||||
M1-100R |
0(≤50) |
85 |
50 |
||||||
M1-225L |
100,125 |
≤50 |
25 |
18 |
1000 |
7000 |
|||
M1-225S |
≤50 |
35 |
22 |
||||||
M1-225H |
≤50 |
50 |
35 |
||||||
M1-225R |
≤50 |
85 |
50 |
||||||
M1-400L |
225,250 |
≤50 |
35 |
25 |
1000 |
4000 |
|||
M1-400S |
≤50 |
50 |
35 |
||||||
M1-400H |
≤100 |
65 |
42 |
||||||
M1-630L |
400 |
≤100 |
35 |
25 |
|||||
M1-630S |
≤100 |
50 |
35 |
||||||
M1-630H |
≤100 |
65 |
42 |
||||||
M1-630R |
≤100 |
100 |
65 |
||||||
M1-800H |
630,700 |
≤100 |
75 |
50 |
|||||
M1-800R |
≤100 |
100 |
65 |
||||||
M1-1250H |
800,1250 |
Three |
≤100 |
100 |
65 |
||||
M1-1600H |
1250,100 |
≤100 |
100 |
65 |
OUTLINE AND INSTALLATION DIMENSIONS
Type |
Outline Dimensions(mm) |
Installation |
|||||||||||||||||||
Front panel connection |
|||||||||||||||||||||
W |
W1 |
L |
L1 |
L2 |
H |
H1 |
H2 |
H3 |
H4 |
C |
D |
E |
F |
G |
I |
W2 |
W3 |
A |
B |
Φd |
|
M1-63S |
76 |
50 |
135 |
170 |
117 |
7 |
4 |
85 |
28.5 |
48 |
22 |
14 |
7.5 |
100 |
75 |
25 |
117 |
3.5 |
|||
M1-63H |
76 |
50 |
135 |
170 |
117 |
82 |
98.5 |
28 |
7 |
4 |
85 |
28.5 |
48 |
22 |
14 |
7.5 |
100 |
75 |
25 |
117 |
3.5 |
M1-100L |
92 |
60 |
150 |
185 |
132 |
68 |
86 |
24 |
7 |
4 |
88 |
35.5 |
50 |
22 |
17.5 |
7.5 |
30 |
129 |
4.5 |
||
M1-100S |
92 |
60 |
150 |
185 |
132 |
68 |
86 |
24 |
7 |
4 |
88 |
35.5 |
50 |
22 |
17.5 |
7.5 |
30 |
129 |
4.5 |
||
M1-100H |
92 |
60 |
150 |
185 |
132 |
86 |
104 |
24 |
7 |
4 |
88 |
35.5 |
50 |
22 |
17.5 |
7.5 |
122 |
90 |
30 |
129 |
4.5 |
M1-100R |
92 |
60 |
150 |
185 |
132 |
86 |
104 |
24 |
7 |
4 |
88 |
35.5 |
50 |
22 |
17.5 |
7.5 |
30 |
129 |
4.5 |
||
M1-225L |
107 |
70 |
165 |
215 |
144 |
86 |
110 |
24 |
5 |
4 |
102 |
31.5 |
50 |
22 |
17 |
9 |
35 |
126 |
5 |
||
M1-225S |
107 |
70 |
165 |
215 |
144 |
86 |
110 |
24 |
5 |
4 |
102 |
31.5 |
50 |
22 |
17 |
9 |
35 |
126 |
5 |
||
M1-225H |
107 |
70 |
165 |
215 |
144 |
103 |
127 |
24 |
5 |
4 |
102 |
31.5 |
50 |
22 |
17 |
9 |
142 |
105 |
35 |
126 |
5 |
M1-225R |
107 |
70 |
165 |
215 |
144 |
103 |
127 |
24 |
5 |
4 |
102 |
31.5 |
50 |
22 |
17 |
9 |
35 |
126 |
5 |
||
M1-400L |
150 |
96 |
257 |
357 |
224 |
105 |
155 |
38 |
8 |
6 |
128 |
64.5 |
89 |
65 |
Φ26 |
44 |
194 |
7 |
|||
M1-400S |
150 |
96 |
257 |
357 |
224 |
105 |
155 |
38 |
8 |
6 |
128 |
64.5 |
89 |
65 |
Φ26 |
198 |
144 |
44 |
194 |
7 |
|
M1-400H |
182 |
116 |
270 |
370 |
234 |
110 |
160 |
43 |
8 |
6 |
134 |
70 |
89 |
65 |
Φ29 |
58 |
200 |
7 |
|||
M1-630L |
182 |
116 |
270 |
370 |
234 |
110 |
160 |
43 |
8 |
6 |
134 |
70 |
89 |
65 |
Φ29 |
58 |
200 |
7 |
|||
M1-630S |
182 |
116 |
270 |
370 |
234 |
110 |
160 |
43 |
8 |
6 |
134 |
70 |
89 |
65 |
Φ29 |
240 |
174 |
58 |
200 |
7 |
|
M1-630H |
182 |
116 |
270 |
370 |
234 |
110 |
160 |
43 |
8 |
6 |
134 |
70 |
89 |
65 |
Φ29 |
58 |
200 |
7 |
|||
M1-630R |
210 |
140 |
280 |
380 |
243 |
106 |
145 |
33 |
30 |
128 |
70 |
243 |
7.2 |
||||||||
M1-800H |
210 |
140 |
280 |
380 |
243 |
106 |
145 |
33 |
30 |
128 |
70 |
243 |
7.2 |
||||||||
M1-800R |
210 |
140 |
280 |
380 |
243 |
106 |
145 |
33 |
30 |
128 |
70 |
243 |
7.2 |
||||||||
M1-1250H |
140 |
393 |
200 |
||||||||||||||||||
M1-1600H |
140 |
393 |
200 |
Accessory code |
Accessory Name |
200、300 |
None |
208、308 |
Alarm Contact |
210、310 |
Shunt Release |
220、320 |
Auxiliary Contact |
230、330 |
Undervoltage Release |
240、340 |
Shunt release Auxiliary Contact |
250、350 |
Shunt release Undervoltage Release |
260、360 |
Two Groups of Auxiliary Contact |
270、370 |
Auxiliary Contact Undervoltage Release |
218、318 |
Shunt Release Alarm Contact |
228、328 |
Auxiliary Contact Alarm Contact |
238、338 |
Undervoltage Release Alarm Contact |
248、348 |
Shunt Release,Aux Contact,Alarm Contact |
268、368 |
Two Groups of Auxiliary Contact,Alarm Contact |
278、378 |
Aux Contact,Undervoltage Release,Alarm Contact |
PROTECTION CHARECTERISTICS
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay, while the magnetic release is the instantaneous operation as shown on table 4(distribution circuit breaker).
Rated current |
Thermodynamic Release |
Operational |
|
1.05In(cold state) |
1.30In(heat state) |
||
10≤In≤63 |
≥1 |
<1 |
10In±20% |
63<In≤100 |
≥2 |
<2 |
|
100<In≤800 |
≥2 |
<2 |
10In±20% |
800<In≤1600 |
≥2 |
<2 |
10In±20% |
WORKING ENVIRONMENT
(1) Altitude≤2000m.
(2) Ambient temperature:+40℃(+45 ℃for ships)~-5℃.
(3) Resistance to moisture.
(4) Resistance to salt spary and oil spary.
(5) Resistance to mould.
(6) Resistance to nuclear radiation.
(7) Maximun salant:?2.5?
(8) Reliable work under earthquake condition(4g).
(9) Ambient environment freeing from exqlosive danger and air or dust which may cause corrosion of metal or weakness of insulation.
(10) Ambient environment freeing from erosio of rain or snow.