Short Description:


Product Detail

Video

Product Tags

Related Video

Feedback (2)

Our purpose would be to offer good quality products at competitive price ranges, and top-notch support to clients around the whole world. We're ISO9001, CE, and GS certified and strictly adhere to their good quality specifications for Thermal Overload Protection For Electric Motors, Single Phase Motor Overload Protection, Ammeter For Ac Current, Our products have exported to North America, Europe, Japan, Korea, Australia, New Zealand, Russia and other countries. Looking forward to build up a good and long term cooperation with you in coming future!
ODM Electric Prepaid Meter Manufacturers - Active and Reactive Frequency Table (Design Paragraph) – Newlink Detail:

Intelligent digital display Power Meter Instruction Manual

Overview

This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit; lower limit; upper and lower limit, 2 digital output, RS485 communication interface, using standard Modbus-RTU protocol, can be directly connected with industrial configuration software, easy to group network, 3. All the way analog output.

product-description1

product-description2

Operating Instructions

1. key definition

Function key SET: It is used to enter the menu, and it is the confirmation key in programming mode.

Shift key: Cycle through the nixie tubes in the selected page, and the selected nixie tubes are flashing.

Increase key ▲: Enter the setting value, change the value of the flashing digital tube (the numbers cycle from 0 to 9).

2. Operation method

Use the menu key SET to select the setting page, use the increase key ▲ to enter the setting value setting, use the shift key and the increase key ▲ to change the digital tube value on the page, adjust to the desired value and press the function key SET to confirm and exit the programming state.

Single/Three Phase Power Factor Meter Instruction Manual

Features

1. Single-phase and three-phase can be set through the panel buttons

2. Display range: C0.000~1.000~L0.000

3. Software adjustment, no internal potentiometer, high precision

4. Optional with communication function. (must be specified when ordering)

5. Optional with upper and lower limit alarm control function

Instructions

1. Press and hold the SET button for 6 seconds to enter the menu, the r-H (for setting direct reading parameters) mark appears, and then press SET again to enter the set value (0005), this value is the displayed value (ie the base value), this You can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value. Press the SET key again to display the r-K (set magnification) mark, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, and you can also use the down key “▽” to change the small value.

Note: If it is a simple function, after completing the operation through the above keys, press the SET key continuously to exit.

2. If you want additional functions, you can continue to complete the operation through the following keys:

Press the SET key again to display the Addr (communication address) sign, and press SET again to enter the set value (0001). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value. Press the SET key again to display the BAUD (baud rate) mark, and press SET again to enter the set value (9600). At this time, you can use the up key “△” to change the large value, or use the down key “▽” to change the decimal value . Press the SET button again to display the ALHL (alarm) sign, press SET again to enter the upper limit alarm setting (AH-Y), if you want to set the lower limit alarm, you can press the up button “△” again to enter the lower limit alarm setting (AL-Y) ), then press SET to display the (ALN) sign, then press SET again to enter the alarm value setting menu (2000). At this time, you can use the up key “△” to change the larger value, or press the down key “▽” Change the decimal value.

Matters needing attention

1. Before use, the meter needs to be powered on for 15 minutes.

2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmful gases.

3. The input wire should not be too long. If the input end of the signal under test is long, please use a twisted pair shielded wire.

4. If the signal is accompanied by high frequency interference, a low frequency filter should be used in the line.

5. When not in use for a long time, please turn on the power for no less than 4 hours every three months.

6. Long-term storage should avoid direct light, and should be stored at -10℃~70℃.

7. If there is no display on the meter, first check the auxiliary power supply to see if the voltage is within the specified range.

8. If the display is abnormal, check whether the input signal is normal and whether the signal terminals are tightened.

9. Unless the PT has enough power, the PT signal cannot be used as an auxiliary power supply at the same time to ensure the normal operation of the instrument.

10. The screws of the current terminals in the CT circuit must be tightened to ensure reliable contact between the incoming and outgoing wires to avoid malfunctions.

11. To calibrate the instrument, the calibration instrument should be better than level 0.1 to ensure the calibration accuracy.

Product In Kind

product-description3

External Dimensions

product-description4


Product detail pictures:

ODM Electric Prepaid Meter Manufacturers - Active and Reactive Frequency Table (Design Paragraph) – Newlink detail pictures


Related Product Guide:

We constantly continually give you essentially the most conscientious client provider, plus the widest variety of designs and styles with finest materials. These initiatives include the availability of customized designs with speed and dispatch for ODM Electric Prepaid Meter Manufacturers - Active and Reactive Frequency Table (Design Paragraph) – Newlink , The product will supply to all over the world, such as: Austria, Zambia, Monaco, Good quality, Good service is always our tenet and credo. We take every effort to control the quality, package, labels etc and our QC will check every detail during producing and before shipment. We are willing to establish long business relationship with those who seek the high quality products and good service. We have set up a wide sales network across European countries, North of America, South of America, Middle East, Africa, East Asia countries.Please contact us now, you will find our professional experience and high quality grades will contribute to your business.
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Abigail from South Korea - 2018.08.12 12:27
    Products and services are very good, our leader is very satisfied with this procurement, it is better than we expected,
    5 Stars By Olivia from Chile - 2018.06.21 17:11
    Write your message here and send it to us

    Related products

    • OEM High Quality Voltmeter 5v Manufacturer - Digital LED Timer – Newlink

      OEM High Quality Voltmeter 5v Manufacturer - D...

      Shape     working power supply A type DC5V ±5%S150mAAC/DC9-12V B type DC5V±5%≤150mA AC/DC9v-220V AC110-220V DC5V±5%≤150mA AC/DC9v-220V AC110-220V Dimensions (width × height × depth mm) 79×42.5×25.5(A)79×42.5×58(B) 74×32×69 Mounting Hole(mm) 76×39.5 70×28 Basic range Customized on request Customized on request Measurement precision ≤0.1% ≤0.1% Input Contact signal or standard TTL high and low level signal Contact signal or standard TTL high and low level signal Display method ...

    • OEM High Quality Power Monitor Meter Factories - Three-Phase Voltage And Current Combination Table (Conventional) – Newlink

      OEM High Quality Power Monitor Meter Factories ...

      Overview The three-phase voltage and current combination meter is a multi-functional electrical measuring instrument with programmable measurement, display and digital communication functions. It can complete electricity measurement, data display, acquisition and transmission, and can be widely used in substation automation, distribution automation, intelligent buildings , Electric energy measurement, management and assessment within the enterprise. The measurement accuracy is 0.5 level, and ...

    • ODM Dc Current Ammeter Suppliers - Digital LED Timer – Newlink

      ODM Dc Current Ammeter Suppliers - Digital LED...

      Shape     working power supply A type DC5V ±5%S150mAAC/DC9-12V B type DC5V±5%≤150mA AC/DC9v-220V AC110-220V DC5V±5%≤150mA AC/DC9v-220V AC110-220V Dimensions (width × height × depth mm) 79×42.5×25.5(A)79×42.5×58(B) 74×32×69 Mounting Hole(mm) 76×39.5 70×28 Basic range Customized on request Customized on request Measurement precision ≤0.1% ≤0.1% Input Contact signal or standard TTL high and low level signal Contact signal or standard TTL high and low level signal Display method ...

    • OEM High Quality Watts Up Power Meter Suppliers - Multifunctional Power Meter (Conventional) – Newlink

      OEM High Quality Watts Up Power Meter Suppliers...

      Overview The multi-function power meter can measure all the commonly used power parameters in the three-phase power grid system with high precision: three-phase voltage, three-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with Communication interface and power pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of co...

    • OEM High Quality Dc Ammeter Shunt Manufacturer - Active and Reactive Frequency Table (Design Paragraph) – Newlink

      OEM High Quality Dc Ammeter Shunt Manufacturer ...

      Intelligent digital display Power Meter Instruction Manual Overview This series of intelligent digital display power meter is a high-precision meter developed for power measurement and display in power grid and automatic control system. It has the advantages of intuitive display, high precision, good stability and strong vibration resistance. CPU digital processing, AC true RMS measurement, CT (PT) can be set through the panel keys. Optional: 1 relay control output, can be set to: upper limit...

    • ODM Direct Current Voltmeter Supplier - Digital LED Timer – Newlink

      ODM Direct Current Voltmeter Supplier - Digita...

      Shape     working power supply A type DC5V ±5%S150mAAC/DC9-12V B type DC5V±5%≤150mA AC/DC9v-220V AC110-220V DC5V±5%≤150mA AC/DC9v-220V AC110-220V Dimensions (width × height × depth mm) 79×42.5×25.5(A)79×42.5×58(B) 74×32×69 Mounting Hole(mm) 76×39.5 70×28 Basic range Customized on request Customized on request Measurement precision ≤0.1% ≤0.1% Input Contact signal or standard TTL high and low level signal Contact signal or standard TTL high and low level signal Display method ...