With our superb management, potent technical capability and strict quality command procedure, we go on to provide our shoppers with trustworthy high-quality, reasonable costs and outstanding services. We goal at becoming considered one of your most trustworthy partners and earning your pleasure for Wireless Electricity Meter, Ct Power Meter, High Current Dc Ammeter, We have been pretty proud of your superior standing from our shoppers for our products' trustworthy quality.
OEM High Quality 3 Wire Digital Voltmeter Suppliers - Active and Reactive Frequency Table (Regular) – Newlink Detail:

Smart Frequency Meter Instruction Manual

Product Features

1. The whole four-digit display

2. Optional with communication function, communication address, baud rate

3. Software adjustment, no internal potentiometer, high precision

4. Software adjustment, no internal potentiometer, high precision

Matters needing attention

1. Before use, the meter needs to be powered on for 15 minutes.

2. Pay attention to prevent vibration and impact, and do not use it in places with excess dust and excess harmful gases.

3. The input wire should not be too long. If the input end of the signal under test is long, please use a twisted pair shielded wire.

4. If the signal is accompanied by high frequency interference, a low frequency filter should be used in the line.

5. When not in use for a long time, please turn on the power for no less than 4 hours every three months.

6. Long-term storage should avoid direct light, and should be stored at -10℃~70℃.

7. If there is no display on the meter, first check the auxiliary power supply to see if the voltage is within the specified range.

8. If the display is abnormal, check whether the input signal is normal and whether the signal terminals are tightened.

9. Unless the PT has enough power, the PT signal cannot be used as an auxiliary power supply at the same time to ensure the normal operation of the instrument.

10. The screws of the current terminals in the CT circuit must be tightened to ensure reliable contact between the incoming and outgoing wires to avoid malfunctions.

Overview

product-description1

product-description2

Product In Kind

product-description3

External Dimensions

product-description4


Product detail pictures:

OEM High Quality 3 Wire Digital Voltmeter Suppliers - Active and Reactive Frequency Table (Regular) – Newlink detail pictures


Related Product Guide:

All we do is usually affiliated with our tenet Buyer to start with, Belief to start with, devoting about the food packaging and environmental defense for OEM High Quality 3 Wire Digital Voltmeter Suppliers - Active and Reactive Frequency Table (Regular) – Newlink , The product will supply to all over the world, such as: Jeddah, Munich, Auckland, We welcome you to visit our company and factory. It is also convenient to visit our website. Our sales team will offer you the best service. If you need more information, please feel free to contact us by E-mail or telephone. We are sincerely hope to establish a good long-term business relationship with you through this opportunity, based on equal, mutual benefit from now till the future.
  • The company comply with the contract strict, a very reputable manufacturers, worthy a long-term cooperation.
    5 Stars By Melissa from Marseille - 2017.06.25 12:48
    The supplier cooperation attitude is very good, encountered various problems, always willing to cooperate with us, to us as the real God.
    5 Stars By Mamie from azerbaijan - 2017.01.11 17:15
    Write your message here and send it to us

    Related products

    • ODM Electrical Multi Meter Factories - Single-phase Ammeter (Conventional) – Newlink

      ODM Electrical Multi Meter Factories - Single-...

      Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crystal display Uses...

    • OEM High Quality Rf Power Meter Suppliers - Single-phase Ammeter (Conventional) – Newlink

      OEM High Quality Rf Power Meter Suppliers - Si...

      Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crystal display Uses...

    • OEM High Quality Portable Electric Meter Supplier - Three -Phase Voltage Table (Design Model) – Newlink

      OEM High Quality Portable Electric Meter Suppli...

      Overview Using AC voltage technology, it is possible to measure the three voltage phases in the power grid, and simply compare them through the panel setting rate. Features, and can complete the network communication with similar PLC and industrial computer. Features Measurement: Three-phase voltage Display: Three rows of LED digital / LCD liquid crystal display A, B, C three-phase voltage Uses: suitable for power grid, automatic control system. Low-voltage three-phase current measurement cir...

    • ODM Smart Prepaid Electricity Meter Manufacturers - Three -Phase Voltage Table (Design Model) – Newlink

      ODM Smart Prepaid Electricity Meter Manufacture...

      Overview Using AC voltage technology, it is possible to measure the three voltage phases in the power grid, and simply compare them through the panel setting rate. Features, and can complete the network communication with similar PLC and industrial computer. Features Measurement: Three-phase voltage Display: Three rows of LED digital / LCD liquid crystal display A, B, C three-phase voltage Uses: suitable for power grid, automatic control system. Low-voltage three-phase current measurement cir...

    • OEM High Quality Line Protection Transformer Protection Manufacturer - Common Type Temperature And Humidity Controller – Newlink

      OEM High Quality Line Protection Transformer Pr...

    • OEM High Quality Multirange Ac Voltmeter Manufacturer - Multifunctional Power Meter (Design version) – Newlink

      OEM High Quality Multirange Ac Voltmeter Manufa...

      Overview The multi-function power meter can measure all the commonly used power parameters in the three-phase power grid system with high precision: three-phase voltage, three-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with Communication interface and power pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of co...