• facebook
  • linkedin
  • Instagram
  • youtube
  • WhatsApp
  • nybjtp

OEM High Quality Digital Voltmeter And Amp Meter Factories - LED Digital Display Meter – Newlink

Short Description:


Product Detail

Video

Product Tags

Related Video

Feedback (2)

Every single member from our large efficiency revenue team values customers' wants and company communication for Dc Volt Meter Price, Dc Motor Protection Circuit, Magnetic Overload Protection, We give priority to quality and customer satisfaction and for this we follow stringent quality control measures. We have in-house testing facilities where our products are tested on every aspect at different processing stages. Owning to latest technologies, we facilitate our customers with customized production facility.
OEM High Quality Digital Voltmeter And Amp Meter Factories - LED Digital Display Meter – Newlink Detail:

ltem/Model (Emerald Backlight) (white backight optional negative display white characters)
Shape  1  2
Working power DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
Dimensions (WwH’Dmm) 79×42.5×25.5 79×42.5×25.5
Mounting hole(mm) 75×39.5 75×39.5
Measurement accuracy ±0.2% of full scale value ±2 words(DC)
+0.5% full scale value ±5 words (AC)
±0.2% of full scale value +2 words(DC)
±0.5% full scale value 15 words(AC)
Basic rangeo DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/300V 200mV/2V/20V/200V/300V
DC current (dired input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
AC current (direct input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
Extended range (external input) AC transfomer. DC shunt Voltage drop module AC transfomer. DC shunt Voltage drop module
Display character height 20×10mm LCD show 20× 10mm LCD show
Features Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
Other +/-polarity automatic switching, optional reading lock function +/-polarity automatic switching, optional reading lock function
ltem/Model (negative emerald green characters) (Negatve white characters can be selected with white backlight)
Shape  1  2
Working power DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
DC5V±5%≤15mA
AC/DC9V-12V AC/DC24V
Dimensions (WwH’Dmm) 79×42.5×25.5 79×42.5×25.5
Mounting hole(mm) 75×39.5 75×39.5
Measurement accuracy ±0.2% of full scale value ±2 words(DC)
+0.5% full scale value ±5 words (AC)
±0.2% of full scale value +2 words(DC)
±0.5% full scale value 15 words(AC)
Basic rangeo DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/300V 200mV/2V/20V/200V/300V
DC current (dired input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
AC current (direct input) 200μA/2mA/20mA/200mA/2A/5A 200μA/2mA/20mA/200mA/2A/5A
Extended range (external input) AC transfomer. DC shunt Voltage drop module AC transfomer. DC shunt Voltage drop module
Display character height 20×10mm LCD show 20× 10mm LCD show
Features Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
Other +/-polarity automatic switching, optional reading lock function +/-polarity automatic switching, optional reading lock function

If the power supply DC5V is used to measure AC300V or AC500V, it is recommended to use the power supply AC9V to measure AC300V or AC500V, which saves 30%-50% of production costs.

(Blue backlight optional negative blue words) (Orange backlight optional negative orange word) (Red backlight optional negative red words) (negative green words)
 1  2  3  4
DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V DC5V±5%≤15mA AC/DC9v-12V AC/DC24V
79×42.5×25.5 79×42.5×25.5 79×42.5×25.5 79×42.5×25.5
75×39.5 75×39.5 75×39.5 75×39.5
±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC)
±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC)
200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V
200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
20×10mm LCD display 20×10mm LCD display 20×10mm LCD display 20×10mm LCD display
Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
(negative blue characters, optional blue backlight) (Negative orange characters, optional orange backlight) (negative red words, backlight optional red) (green backlight word)
 5  6  7  8
DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V DC5V±5%≤15mA AC/DC9C-220V AC110-220V
79×42.5×58 79×42.5×58 79×42.5×58 79×42.5×58
75×39.5 75×39.5 75×39.5 75×39.5
±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC) ±0.2% of full scale value ±2 words (DC)
±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC) ±0.5% full scale value ±5 words (AC)
200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V 200mV/2V/20V / 200V/500V
200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V 200mV/2V/20V / 200V/300V
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
20×10mm LCD display 20×10mm LCD display 20×10mm LCD display 20×10mm LCD display
Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation Large-screen LCD display, embedded installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

3 and a half LED digital display meter product selection

The main technical parameters

Shape  1  2
Working power DC5V±5%≤ 100mA AC/DC9V-12V AC/DC24V-48V DC5V±5%≤ 100mA AC/DC9V-220V AC110-220V
Dimensions (W’H’Dmm) 79×42.5×25.5 79×42.5×58
Mounting hole(mm) 76×39.5 76×39.5
Measurement accuracy ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
Basic range DC voltage (direct input) 200mv / 2V / 20V / 200V / 500V 200mv / 2V / 20V / 200V / 500V
AC voltage(direct input) 200mv / 2V / 20V / 200V / 300V 200mv / 2V / 20V / 200V / 500V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 10A
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 10A
Extended range (external input) AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
Display character height 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Features Fully enclosed gray shell, curved design, embedded installation Fully enclosed gray shell, curved design, embedded installation
Other +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
Shape  1  2
Working power DC5V±5%AC/DC9V-12V AC/DC24V DC5V±5%≤ 100mA
Dimensions (W’H’Dmm) 48×26×35 48×26×23
Mounting hole(mm) 47×23 47×23
Measurement accuracy ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 digits (DC)
Basic range DC voltage (direct input) 200mv / 2V / 20V / 200V / 500V 200mv / 2V / 20V / 200V
AC voltage(direct input) 200mv / 2V / 20V / 200V / 300V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A
Extended range (external input) AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
Display character height 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Features Delicate appearance, small and exquisite, embedded design Delicate appearance, small and exquisite, embedded design
Other +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

If the power supply DC5V is used to measure AC300V or AC500V, it is recommended to use the power supply AC9V to measure AC300V or AC500V, which saves 30%-50% of production costs.

 1  2  3  4
DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%AC/DC9V-12V AC/DC24V DC5V±5%≤100mA
71×40×28 71×40×58 46×26×20 48×29×30
68×38 68×38 42×23 46×265
±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V
200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/10A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/10A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Fully enclosed gray shell, curved design, embedded installation The shell size is the same as that of the 85L/85C series pointer head, which can be directly interchanged Exquisite shape, small and exquisite, embedded design Exquisite shape, small and exquisite, embedded design
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function
 1  2  3
DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-12V DC5V±5%≤100mA AC/DC9V-220V AC110-220V
72×36×20 79×42.5×20 74×32×69
69×34 76×39.5 70×28
±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC) ±0.2% full scale value ±2 words (DC), ±0.5% full scale value ±5 words (AC)
200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V 200mV / 2V / 20V / 200V /500V
200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V 200mV / 2V / 20V / 200V /300V
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A 200μA / 2mA / 20mA/ 200mA/ 2A/5A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue) 0.56LED red (optional green, yellow or blue)
Plug-in self-locking device, easy to install Black shell, embedded installation, elegant appearance Fully enclosed gray housing, flat design, ejector clamp installation
+/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function +/- polarity automatic switching, optional reading lock function

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

4 and a half LED digital display meter product selection

The main technical parameters

Shape  product description1  product description2
Working power DC5V±5%≤150mA DC5V土5% S 150mA AC/DC9V-12V AC/DC24V-48V
Dimensions (W’H'Dmm) 79×42.5×25.5 79×42.5×58
Mounting hole(mm) 76×39.5 76×39.5
Measurement accuracy ±0.03% full scale value ±2 words(DC) ±0.03% full scale value ±2 words(DC) ±0.5% full scale value ±35 words(AC)
Basic range DC voltage (direct input) 200mV/2V/20V/200V/500V 200mV/2V/20V/200V/500V
AC voltage(direct input) 200mV/2V/20V/200V/500V
DC current (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A 200μA/ 2mA/20mA/ 200mA/2A/ 5A
ACcurrent (direct input) 200μA/ 2mA/20mA/ 200mA/2A/ 5A
Extended range (external input) DC shunt, voltage drop module AC Transformer, DC Shunt,Voltage Drop Modu
Display character height 0.56LED red(optional green,yellow or blue)
Features Totally enclosed gray shell, curved design, embedded installation
Other +/-polarity automatic switching, optional reading lock function
Shape

product description3

product description4

Working power DC5V±5%≤150mA AC/DC9V-220V AC110-220V DC5V±5%≤150mA AC/DC9V-220V AC110-220V
Dimensions (width x height x depth mm) 96×48×86 96×48×117
Mounting Hole(mm) 90×45 91×44
Measurement precision ±0.5% full scale value ±35 words (AC) ±0.5% full scale value ±35 words (AC)
Basic range (direct input) AC200mV-500V AC200μA-5A AC200mV-500V AC200μA-5A
Extended range (external input) AC transformer AC transformer
Frequency Range 45-400Hz AC 45-400Hz AC
Display method 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue)
Product Features Fully enclosed gray shell, flat design, screw-tight installation Fully enclosed gray shell, flat design, screw-tight installation
Others +/- polarity automatic conversion, optional reading lock function. Optional with RS-485 interface, upper limit, lower limit setting, with transmitter output function. +/- polarity automatic conversion, optional reading lock function. Optional with RS-485 interface, upper limit, lower limit setting, with transmitter output function.
 product description5

 product description6

 product description7

 product description8

DC5V±5%≤100mA AC/DC9V-12V AC/DC24V-48V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%≤100mA AC/DC9V-220V AC110-220V DC5V±5%≤100mA AC/DC9V-220V AC110-220V
74×32×69 9×48×77 96×48×86 95×.48×117
70×28 9×45 90×45 91×44
±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC) ±0.03% of full scale value ±2 words (DC)±0.5% full scale value ±35 words (AC)
200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/750V
200mV/2V/20V /200V/300V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/500V 200mV/2V/20V /200V/750V
200μA/ 2mA/ 20mA/ 200mA/2A/ 5A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 15A
200μA/ 2mA/ 20mA/ 200mA/2A/ 5A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 10A 200μA/ 2mA/ 20mA/ 200mA/2A/ 15A
AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module AC Transformer, DC Shunt, Voltage Drop Module
0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue) 0.56LED red (optional green. yellow or blue)
Fully enclosed idle ash shell, flat design, ejector clamp installation Fully enclosed gray shell, flat design, embedded installation Fully enclosed gray housing, flat design, screw-fastened installation Fully enclosed gray housing, flat design, screw-fastened installation
+/- polarity automatic switching. Optional reading locking function +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function. +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function. +/- polarity automatic switching. Optional reading locking function. Optional with RS-485 interface, upper and lower limit setting, with transmitter output function.

Recommendation: The digital AC ammeter is in the measurement range of 10A-300A, and it is recommended to use a precision current transformer (see pages 49-51 for technical specifications). The production cost can be saved by 30%-50%.

3 and a half LED digital display meter

The main technical parameters

shape

 product description1

 product description2
working power supply

AC/DC9V-12V AC/DC24V AC-220V
(Two-wire direct measurement. No working voltage required)

AC/DC9V-12V AC/DC24V AC-220V
(Two-wire direct measurement. No working voltage required)

Dimensions (width x height x depth mm)

70×40×25

70×40×25
Mounting Hole(mm)

68×38

68×38

product description3

Suggestion: The digital AC ammeter is in the measurement range of 10A-300A. It is recommended to use a precision current transformer (see pages 49-51 for technical specifications), which saves 30%-50% in production costs.

Shape

 product description4

Working power AC220v
Dimensions (width x height x depth mm) 96×48×117
Mounting Hole(mm) 90×43
Measurement precision Main 0.2% full scale value ±2 words (DC). ±0.5% full scale value ±5 words (AC)

product description5


Product detail pictures:

OEM High Quality Digital Voltmeter And Amp Meter Factories - LED Digital Display Meter – Newlink detail pictures


Related Product Guide:

The very rich projects management experiences and one to one service model make the high importance of business communication and our easy understanding of your expectations for OEM High Quality Digital Voltmeter And Amp Meter Factories - LED Digital Display Meter – Newlink , The product will supply to all over the world, such as: Cologne, Greek, Indonesia, With the first-class products, excellent service, fast delivery and the best price, we have won highly praise foreign customers'. Our products have been exported to Africa, the Middle East, Southeast Asia and other regions.
  • This is a reputable company, they have a high level of business management, good quality product and service, every cooperation is assured and delighted!
    5 Stars By Penny from Grenada - 2017.09.28 18:29
    Superb technology, perfect after-sales service and efficient work efficiency, we think this is our best choice.
    5 Stars By Marco from Amman - 2018.12.11 11:26
    Write your message here and send it to us

    Related products

    • ODM Single Phase Power Meter Factory - Single-Phase Current (Design Version) – Newlink

      ODM Single Phase Power Meter Factory - Single-...

      Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crystal display Uses: suitable...

    • OEM High Quality Digital Watt Meter Suppliers - Three-Phase Ammeter (Conventional) – Newlink

      OEM High Quality Digital Watt Meter Suppliers -...

      Overview The three-phase ammeter adopts the AC sampling technology to measure the true RMS value, and can measure the three-phase current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: Three-phase current Display: Three rows of L...

    • OEM High Quality Shunt Amperemeter Manufacturers - Single-Phase Multi-Function Power Meter (Conventional) – Newlink

      OEM High Quality Shunt Amperemeter Manufacturer...

      Overview The single-phase multi-function meter can measure all the commonly used power parameters in the power grid system with high precision: single-phase voltage, single-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with communication Interface and energy pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of conv...

    • OEM High Quality Small Electric Meter Manufacturers - Three-Phase Voltage And Current Combination Table (Conventional) – Newlink

      OEM High Quality Small Electric Meter Manufactu...

      Overview The three-phase voltage and current combination meter is a multi-functional electrical measuring instrument with programmable measurement, display and digital communication functions. It can complete electricity measurement, data display, acquisition and transmission, and can be widely used in substation automation, distribution automation, intelligent buildings , Electric energy measurement, management and assessment within the enterprise. The measurement accuracy is 0.5 level, and ...

    • ODM Isolator Converter Factories - Common Type Temperature And Humidity Controller – Newlink

      ODM Isolator Converter Factories - Common Type...

      Application

    • OEM High Quality Portable Electric Meter Supplier - Three -Phase Voltage Table (Design Model) – Newlink

      OEM High Quality Portable Electric Meter Suppli...

      Overview Using AC voltage technology, it is possible to measure the three voltage phases in the power grid, and simply compare them through the panel setting rate. Features, and can complete the network communication with similar PLC and industrial computer. Features Measurement: Three-phase voltage Display: Three rows of LED digital / LCD liquid crystal display A, B, C three-phase voltage Uses: suitable for power grid, automatic control system. Low-voltage three-phase current measurement cir...