Safety Guidance

Information about your personal safety
Due to different conditions or requirements, this manual cannot cover all the safety matters related to the operation of this instrument, but it is very important to understand the following items to ensure your personal safety and prevent damage to the instrument. These items are highlighted with a triangular safety symbol, depending on the degree of potential hazard indicated.

Environmental Indicators

Working Humidity  ≤ 75%
Storage Humidity  ≤ 95%
Operating Temperature  -10°C - +50°C
Storage Temperature  -30°C - +70°C
International standardIEC  62053-21
Domestic Standard  GB/T17215.321-2008
Accuracy Class  1
Dustproof and Waterproof  IP 51
Protective Insulation Encapsulation Type  Ⅱ

Technical Parameters and Display Type

Model (LCDDisplay)
Reference Voltage (Un) 220V    230V    240V
Operating Voltage 181/279V AC (3~)
Rated Current (Ib)   2.5   5A  10A  15A  20A   30A
Maximum Current (Imax) 10A  20A  40A  60A  80A   100A
Starting Current ≤0.004b(Direct Access)
Withstand Overload Current 30Imax    0.01s
Working Frequency   50Hz±10%
Internal Power Consumption ≤2W / 10VA
Pulse Constant 1000imp
RS485 Port  23(A)and24(B)
Data Storage Time >20 Years

LCD Display

1st Screen displays ID address                  Add         001
2nd Screen displays baud rate                   bd          9600
3rd Screen displays constant                    CoSE        1000imp

The fourth screen keeps displaying

4th Screen displays the total amount of electricity   000000.00   kWh

Intrinsic Error

Single phase balanced load

0.05Ib             Cosφ = 1        ±1.5%

0.1Ib              Cosφ = 0.5L     ±1.5%

Cosφ = 0.8C     ±1.5%

0.1Ib - Imax        Cosφ = 1        ±1.0%

0.2Ib - Imax        Cosφ = 0.5L     ±1.0%

Cosφ = 0.8C     ±1.0%

Outline and Structure

a5 A: Front panel

B: Cover

C:Bottom

D: Seal

a6 Front panel       Flame-retardant PC

Cover            Flame-retardant ABS or PC

Bottom           Flame-retardant ABS or PC

Dimension        89.9mmx35mmX72mm

Weight            0.12 Kg (Net Weight)

Terminal Notice
1/3 Input/output
4/5 RS485 port
6/7 Pulse output
8/9 Neutral line

rail (1)

rail (2)

rail (3)

rail (4)

rail (5)

rail (6)

rail (7)

rail (8)

rail (9)

rail (10)

rail (11)

rail (12)

rail (13)

rail (14)

rail (15)


  • Previous:
  • Next:

  • product name

    product model

    basic function

    remarks

    Single-phase electricity meter

    NLK13521-1

    图片18Single P level

    Direct and accurate measurement of active power rated at 50H Z or 60H Z 1.5 (6) A, 5 (20) A, 5 (25) A, 5 (30) A, 5 (32) A, 40 (100)

    Accuracy is level 0.5

    Total electrical power is displayed by a 6 + 1-bit LCD

    Length * in width * 90mm * 18mm * 66mm in height

    NLK13521-2

    图片19Class 2P

    Length * width * height 75mm * 18mm * 55mm respectively

    NLK13521-4

    图片20Level 4P

    Length * width * height of 91mm * 76mm * 74mm respectively

    Write your message here and send it to us

    Related products

    • Intelligent lighting control module

      Intelligent lighting control module

      Overview The appearance of this product is a plastic shell, and it uses a grid shell to facilitate internal heat dissipation: it is equipped with a standard 35mm nickname phase guide rail groove, which is easy to install and can realize lighting control or curtain control for 4/8/12/16 channels, etc. The current of each circuit can reach 0-20A: when the current of the controlled light or electrical equipment is greater than 20A, it can be connected to a relay or a co...

    • Microcomputer Harmonic Elimination Device

      Microcomputer Harmonic Elimination Device

      Functions and Features ●Modular design, compact structure, advanced technology, high-speed 32-bit ARM core processor ensures real-time operation and action accuracy. ●Real-time monitoring of system status, real-time calculation, accurate judgment of low-frequency, fundamental frequency, high-frequency resonance faults in the system, and timely action. ●Real-time display of three-phase voltage, opening voltage, can accurately determine grounding, overvoltage and under...

    • Intelligent Dehumidification Device Intelligent Oil Pumping Device Mini

      Intelligent Dehumidification Device Intelligent...

      Overview Intelligent dehumidification device is the use of semiconductor refrigeration dehumidification mode, the humid air in the closed space under the action of the fan inhalation dehumidification air duct, the water vapor in the air through the semiconductor refrigeration mechanism condensed into water, and then through the guide pipe through the cabinet, can achieve a good dehumidification effect. When there is no manual open dehumidification function: when the ...

    • Three-Phase Voltage And Current Combination Table (Conventional)

      Three-Phase Voltage And Current Combination Tab...

      Overview The three-phase voltage and current combination meter is a multi-functional electrical measuring instrument with programmable measurement, display and digital communication functions. It can complete electricity measurement, data display, acquisition and transmission, and can be widely used in substation automation, distribution automation, intelligent buildings , Electric energy measurement, management and assessment within the enterprise. The measurement accuracy is 0.5 level, and ...

    • Single-Phase Current (Design Version)

      Single-Phase Current (Design Version)

      Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crys...

    • 4P type single three-phase rail meter

      4P type single three-phase rail meter

      Safety Guidance Information about your personal safety Due to different conditions or requirements, this manual cannot cover all the safety matters related to the operation of this instrument, but it is very important to understand the following items to ensure your personal safety and prevent damage to the instrument. These items are highlighted with a triangular safety symbol, depending on the degree of potential hazard indicated. ...