• facebook
  • linkedin
  • Instagram
  • youtube
  • WhatsApp
  • nybjtp

Products

  • Single Phase Voltmeter (Conventional)

    Single Phase Voltmeter (Conventional)

    Overview The smart voltmeter adopts AC sampling technology, can measure the voltage in the power grid, and can set the magnification through the panel buttons, which is very cost-effective. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: s...
  • Single-Phase Current (Design Version)

    Single-Phase Current (Design Version)

    Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crystal display Uses: suitable...
  • Single-phase Ammeter (Conventional)

    Single-phase Ammeter (Conventional)

    Overview The smart ammeter adopts AC sampling technology, which can measure the current in the power grid. It has the characteristics of convenient installation, simple wiring, convenient maintenance, small amount of engineering, field programmable input parameters, etc., and can complete the networking communication with different PLCs and industrial computers in the industry. Features Measurement: single-phase current Display: a row of LED digital / LCD liquid crystal display Uses...
  • Microcomputer Harmonic Elimination Device

    Microcomputer Harmonic Elimination Device

    Overview

    In the power system, ferromagnetic resonance occurs frequently, and overvoltage occurs during resonance, which seriously threatens the safety of the system. Ferromagnetic resonance overvoltage can occur in any system from 3 to 220 kV, especially in power grids of 35 kV and below, almost all internal overvoltage accidents are caused by ferromagnetic resonance. The overvoltage caused by ferromagnetic resonance is long-lasting and may even exist for a long time. In the frequency division resonance, the general overvoltage is not high, but the current of the PT is large, which is easy to cause the PT to overheat and explode; in the fundamental wave and frequency multiplication resonance, the general current is not large, but the overvoltage is very high, which often damages the equipment insulation. , causing a serious accident.

    The power microcomputer harmonic elimination device is a new type of intelligent power resonance elimination device developed by our company. It is simple and convenient to use, requires no maintenance, can quickly eliminate ferromagnetic resonance of various frequencies, and has high accuracy. At the same time, the relevant information can be printed or transmitted to the superior monitoring system through the communication interface according to the user’s needs, which is suitable for unattended substations.

  • Intelligent Dehumidification Device Intelligent Oil Pumping Device Mini

    Intelligent Dehumidification Device Intelligent Oil Pumping Device Mini

    Overview Intelligent dehumidification device is the use of semiconductor refrigeration dehumidification mode, the humid air in the closed space under the action of the fan inhalation dehumidification air duct, the water vapor in the air through the semiconductor refrigeration mechanism condensed into water, and then through the guide pipe through the cabinet, can achieve a good dehumidification effect. When there is no manual open dehumidification function: when the ambient humidity is higher...
  • Intelligent Dehumidification Deviceintelligent Oil Pumping Deviceconventional

    Intelligent Dehumidification Deviceintelligent Oil Pumping Deviceconventional

    Summary Intelligent dehumidification device is the use of semiconductor refrigeration dehumidification mode, the closed space of the wet air in the fan under the action of the fan, the air water vapor through the semiconductor refrigeration mechanism after condensing into water, and then eliminate the cabinet through the guide pipe, can achieve a good dehumidification effect. Cooling type: F01 is set at 0. Meanwhile, the dehumidification device is automatically started when the ambient humidi...
  • Small Current Grounding Line Selection Device

    Small Current Grounding Line Selection Device

    Overview

    Small current wire selection device is an integral part of the industrial field circuit protection system, the device can accurately determine the location of the fault when the circuit system occurs grounding (arc or metallic) phenomenon, and the information for remote transmission, so as to facilitate the maintenance of the site personnel.

    1.1. Function and characteristics

    The structure of the device adopts modular design, and the main controller adopts 16-bit high performance single chip computer with high speed data acquisition module. Among the modules, CAN communication methods with redundant verification and multi-master transmission are used for data exchange and sharing.The panel uses the display screen and a simple 5-key operation function for man-machine dialogue.

    The system adopts double watchdog mode to detect the operation of the system; wide working input voltage, high current signal measurement accuracy; fault and setting information memory function; real-time data and fault data remote transmission function.

  • Indoor High Voltage Live Display

    Indoor High Voltage Live Display

    Product Details Overview This product is a HX2 phase comparator (PC) designed and produced by our company according to the requirements of users, which is used in conjunction with the DXN80 series of indoor high-voltage live display devices (the indicator panel sets the phase test end). It is suitable for substations and power distribution stations (especially when cables enter the line) that are equipped with dual power supplies and multiple power supplies for indoor 3.6, 7.2, 12, 40.5kV,...
  • H Series Three-Phase 380V Frequency Converter

    H Series Three-Phase 380V Frequency Converter

    Selection notice 1. Motors with capacitors cannot use this inverter for speed regulation 2. Fan, water pump, smoke machine, conveyor belt, assembly line, you can choose the same power model 3. For large and heavy loads such as compressors, sewage processors, injection molding machines, crushers, ball mills, winches, rolling mills, Roots fans, etc., it is recommended to increase the model of 1~2 gears Function Description Name Function Description Edit/exit Level 1 menu entry or...
  • A Series Three-Phase 380V Frequency Converter

    A Series Three-Phase 380V Frequency Converter

    Function Description Name Function Description Edit/exit Level 1 menu entry or exit Confirm Enter the menu screen, set the parameters to confirm Numerical addition/subtraction Data or function code increment/decrement Displacement In the stop display interface and the running interface, you can move to the left to cyclically select the displayed parameters. When modifying the parameters, you can select the parameter modification bit. Run In keyboard mode operation, it i...
  • Single-Phase Multi-Function Power Meter (Design Version)

    Single-Phase Multi-Function Power Meter (Design Version)

    Overview The single-phase multi-function meter can measure all the commonly used power parameters in the power grid system with high precision: single-phase voltage, single-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with communication Interface and energy pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of conv...
  • Single-Phase Multi-Function Power Meter (Conventional)

    Single-Phase Multi-Function Power Meter (Conventional)

    Overview The single-phase multi-function meter can measure all the commonly used power parameters in the power grid system with high precision: single-phase voltage, single-phase current, active power, reactive power, power factor, grid frequency, active energy, reactive energy, and with communication Interface and energy pulse output function. Adopt MODBUS-RTU communication protocol to realize LED/LCD on-site display and remote RS-485 digital communication. It has the characteristics of conv...