Working principle
The transmitter circuit module is composed of amplification unit, linearization unit, voltage/current conversion, self-calibration circuit, voltage adjustment unit and reverse protection circuit. The compensator, which uses thermal resistance as the temperature measuring element, also includes an R/V conversion unit.
Features
(1) Wide working environment temperature: -30°C~+120°C
(2) With a high-precision cold junction compensation circuit, the absolute error of the full temperature range is ±0.5°C (S thermocouple ±0.8°C);
(3) Advanced nonlinear correction circuit, the output signal has a linear relationship with the measured temperature.
(4) Built-in drift self-correction system to ensure measurement accuracy in the entire working temperature range;
(5) With a special heat control mechanism, it can effectively control the heat conduction;
(6) Encapsulated with epoxy resin, corrosion-resistant, shock-resistant, high reliability;
(7) It has a wide range of applications. It can not only form an integrated on-site installation structure with thermocouples and thermal resistances, but also be installed in testing equipment as a functional module.
(8) The unique anti-interference circuit design ensures that the transmitter can work safely and reliably under various interferences; it especially has an anti-electromagnetic interference unit, which is suitable for modern environments with serious electromagnetic pollution.
Technical indicators
1. Basic error: ±0.2%, ±0.5%
2. Effect of environmental temperature change: 0.2 level 0.02 %FS/℃
0.5 grade 0.05%FS/℃
3. Output signal: 4~20mA, two-wire transmission;
4. Load resistance: O~600Ω
5. Power supply: 12~36VDC;
6. Working environment:
(1) Ambient temperature: -25~+85°C (ordinary temperature transmitter)
Ambient temperature: -30~+120°C (high temperature ambient temperature transmitter)
⑵ Relative humidity: 5~95%RH without condensation;
7.Explosion-proof grade: intrinsically safe iallCT5;
Shape
Overview
This series of modules is miniaturized and adopts the international general DIN rail installation standard. It has a very high performance-price ratio, adopts advanced SMD technology, and works very reliably and stably. It is an ideal supporting unit for intelligent regulators and DCS systems.
Features
Input, power supply, and output are isolated from each other Input overcurrent protection dynamic response time is less than 0.1S
Shape
General technical conditions
Precision | ±05%F·S |
Insulation strength |
Between input, output and power supply, AC1500V/1 minute |
linear | ±0.1 %F·S |
Insulation resistance |
Between input, output and power supply, 100MΩ (DC500V) |
Load Resistance | 250~750Ω |
Consumption of utility |
1.5W (one way) |
Temperature Coefficient | <100ppm/℃ |
Power supply |
DC24V±10% |
Response time | <0.1S (0-9%) |
Operating temperature |
0-40℃ <95%RH |
Models and Specifications
Name |
Input signal |
Output signal | Function |
Distributor (single channel) |
4~20mADC |
4~20mADC or 1~5VDC |
It provides distribution power to the two-wire transmitter and converts the signal isolation of the transmitter to the output |
Distributor (dual channel) |
4~20mADC |
4~20mADC or 1~5VDC | |
Distributor (one into two out) |
4~20mADC |
4~20mADC or 1~5VDC | |
Distributor/Isolator |
4~20mADC |
4~20mADC or 1~5VDC | |
Isolator (single channel) |
4~20mADC |
4~20mADC or 1~5VDC |
nput and output signal isolation conversion |
Isolator (dual channel) |
4~20mADC |
4~20mADC or 1~5VDC | |
Isolator (one in two out) |
4~20mADC |
4~20mADC or 1~5VDC | |
Isolator (single channel) |
1~5VDC |
4~20mADC or 1~5VDC | |
Isolator (dual channel) |
1~5VDC |
4~20mADC or 1~5VDC | |
Thermocouple Transmitter |
Thermocouple (single input) |
4~20mADC or 1~5VDC (dual isolated output) |
Converts the transmitter’s temperature signal isolation to an output |
Thermal resistance transmitter |
Thermal resistance (single input) |
4~20mADC or 1~5VDC (dual isolated output) |
Overview
The distributor is a miniaturized card-mounted instrument. Its main function is to provide an isolated power supply for the two-wire transmitter installed on site through a DC converter, and at the same time deliver the 4~20mADC from the two-wire transmitter. The signal is converted into an isolated 1~5VDC/4~20mA DC signal, which is supplied to indicators, recorders, analog regulators, and DCS systems, and is widely used in industrial production process detection and control systems. Therefore, this distribution device is an indispensable instrument variety that constitutes a non-explosion-proof automatic control system.
The isolator is a miniaturized card-mounted instrument, the main function is to convert 4~20mADC signal or 1~5VDC signal into mutually isolated 4~20mADC or 1~5VDC output supply indication, recorder, analog regulator, programmable Single/multi-loop digital regulators, distributed control systems and industrial process control machines, etc., and form various automatic monitoring and control systems. Therefore, this isolator is an indispensable instrument variety for non-explosion-proof automatic control systems.
Input and output range
Input signal: 0~5V, 1~5V, 0~10mA, 0~20mA, 4~20mA, 0~10V, -5V~+5V, -10V~+10V and other user-specific specifications.
Output signal: 0~5V, 1~5V, 0~10v, -10~+10V, 0~10mA,
~20mA, 4~20mA, 20~4mA, 5~0V and other user-specific specifications.
Power supply: DC 24v, 15V, 12V, ±12v, AC 220V or other user-specific specifications.
Ordering model: AM-T-input signal/output signal [24V DC power supply if not specified
The main technical parameters
Input impedance: ≥100KΩ (voltage input) <50Ω (current input)
Temperature coefficient: 150ppm/C
Frequency response: <2000Hz
Input load resistance: ≥5KΩ (voltage output) ≤250Ω (current output, specify when ordering for special requirements)
Accuracy: 0.2%
Linearity: 0.1%
Isolation voltage: 2000vDC (1 minute) (input, output, power three-party isolation)
Working temperature range: 0~50℃
Power supply voltage: 24VDC±10%
Power consumption: <40mA (excluding output current)
Principle block diagram
product name |
product model |
basic function |
remarks |
|
DC current separator |
NLK1522 |
Input all DC flow, output all DC small signal, power DC24 power supply |
Length: * width: * height: 108mm*25.4mm: * 47mm |
|
AC voltage isolator |
NLK1520 |
Input all AC voltage, output small DC signal, power supply DC24 |
||
DC voltage separator |
NLK1521 |
Input all DC voltage, output small DC signal, power supply DC24 |
||
Second-line isolation device |
NLK1525 |
Input a second line system, output a road DC signal, Power supply DC24 power supply |
||
AC current separator |
NLK1526 |
Input all AC current, output small DC signal, power supply DC24 |
||
(passive) passive isolator |
NLK1562 |
Input one DC signal and output one DC signal |
||
potentiometer signal isolator |
NLK9020 |
Input a road potentiometer, output a road DC signal, power supply DC24 power supply |
||
Thermal resistance isolator |
NLK9050 |
Input thermal resistance, output DC signal, power DC24 power |
||
Thermocouple isolator |
NLK9060 |
Input a thermocouple, output a DC signal, power supply DC24 power supply |
||
Resistance signal isolator |
NLK2020 |
Input one road resistance or potentiometer signal, output one road DC small signal, power supply DC24V |
||
product name |
product model |
basic function |
remarks |
|
Super Pu-type signal isolator |
NLK1622 |
Input one road DC signal, output one road DC signal, power supply AC / DC220 or DC24V |
Length * width * height 106mm*12.5mm * 112mm |
|
Super Pu type thermal power resistance separator |
NLK169050 |
Input one road thermal resistance signal, output one road DC signal, power supply AC / DC220 or DC24V |
||
Super Pu type thermocouple separator |
NLK169060 |
Input one road thermocouple signal, output one road DC signal, power supply AC / DC220 or DC24V |
||
Safety gate signal separator |
NLK1822 |
Input a DC signal, output a DC signal, power DC24V, detection input and operation output |
Length, * width, * height, 122mm * 18mm * 96mm |
|
Thermoelectric resistance safety gate |
NLK189050 |
Input one road thermal resistance signal, output one road DC signal, power supply DC24V |
||
Thermocouple safety gate |
NLK189060 |
Input one road thermocouple signal, output one road DC signal, power supply AC / DC220 or DC24V |
||
Pluggable signal isolator |
NLK1722 |
The full signal isolator inputs one DC signal, output DC signal, power supply AC / DC220 or DC24V |
Length, * width, * height, 85mm * 23mm * 103mm |
|
Plug-in thermal resistance isolator |
NLK179050 |
The full signal isolator inputs one thermal resistance signal, one DC signal, power supply AC / DC220 or DC24V |
||
Plug-in thermal resistance isolator |
NLK179060 |
The full signal isolator inputs one-way thermocouple signals and outputs one-way DC signal power supply AC / DC220 or DC24V |
||
Full signal isolator |
NLK15241 |
Input one road DC signal, output one road DC signal, power supply AC / DC220 or DC24V |
Length * in width * 99mm * 35mm * 115mm in height |
|
Full signal isolator |
NLK15242 |
Input one DC signal and output two DC signals, power supply AC / DC220 or DC24V |
||
Full signal isolator |
NLK15244 |
Input one-way DC signal, output four-way DC signals, power supply AC / DC220 or DC24V |
||
Full signal isolator |
NLK15252 |
Input one second line system, output two DC signals, power supply AC / DC220 or DC24V |
||
(passive) passive isolator |
NLK15622 |
Input a primary DC signal, Output the two-way DC signals |
||
DC isolator |
NLK21522 |
Input two DC currents, output two small DC small signals, power supply AC / DC220 or DC24V |
||
Second-line isolation device |
NLK21525 |
Input two two lines, output two DC signals, power AC / DC220 or DC24V |
||
Thermal resistance isolator |
NLK90501 |
Input one thermal resistance, output one DC signal, power supply AC / DC220 or DC24V |
||
Thermal resistance isolator |
NLK90502 |
Input one thermal resistance, output two DC signals, power supply AC / DC220 or DC24V |
||
Thermocouple isolator |
NLK90601 |
Input one road thermocouple, output one road DC signal, power supply AC / DC220 or DC24V |
||
Thermocouple isolator |
NLK90602 |
Input one thermocouple, output two DC signals, power supply AC / DC220 or DC24V |
||
Thermocouple temperature transmitter |
SBWR |
Integrated module temperature transmitter Basic error soil 0.2%, 0.5%, environmental temperature change, 0.20.02%FS / ℃, 0.50.05FS / ℃, output signal: 4~20mA, second line transmission; load resistance: 0~600 power supply: 12~36VDC; working environment |
Φ 45mm*15mm |
|
Thermal resistance temperature transmitter |
SBWZ |